Source smarter with
Leverage AI to find the perfect product match in seconds
Matches from over 100 million products with precision
Handles queries 3 times as complex in half the time
Verifies and cross-validates product information
Get the app
Get the Alibaba.com app
Find products, communicate with suppliers, and manage and pay for your orders with the Alibaba.com app anytime, anywhere.
Learn more

Wfs 50 incinerator

(80 products available)

About wfs 50 incinerator

Types of WFS 50 Incinerators

An incinerator performs waste-to-energy conversion processes that burn waste at high temperatures to produce heat or ash. WFS 50 incinerators are a category of waste-fuel incinerators that come in different designs and options to meet diverse environmental needs and regulatory requirements worldwide.

  • The WFS 50/1000 Chassis Incinerator

    This horizontal chassis WFS 50/WFS 1000 incinerator model is mounted on an open chassis. It has an easily movable design so that the location of the waste treatment facility can be changed anytime without incurring much extra cost. The slide rail enables the unit to move around freely and also to easily connect water pipes and electric power.

  • The WFS 50/1000 Container Incinerator

    The WFS 50/WFS 1000 container chassis model is designed like a small moving house. This portable design can help users change the location of the waste treatment facility as well as the incinerator facilities together, making the whole project easier and faster.

    This container-style device can guarantee stable waste incineration and environmental protection even in remote areas. It provides a reliable waste disposal solution for users wherever they are.

Specification and maintenance of the WFS 50 incinerator

The WFS 50 incinerator has several specifications in terms of design, weight, temperature, fuel, and more.

  • Overall size: The overall size of the WFS 50 incinerator is approximately 3.07m (length) x 1.17m (width) x 1.42m (height). Its size allows easy installation and use for various businesses.
  • Weight: The weight of the WFS 50 incinerator is approximately 850kg. Larger and heavier than small-scale ones, the WFS 50 is built to handle industrial levels of waste.
  • Temperature: The WFS 50 can produce a primary chamber combustion temperature of around 850°C-1000°C. Some models or pieces may allow for higher maximum temperatures. Maintaining the proper burning temperature is vital for safely and completely incinerating waste.
  • Fuel: The WFS 50 model offers several incinerator types based on fuel. Therefore, it can support various fuels, including natural gas, propane, LPG, solar energy, pyroligneous acid, and biogas, making it suitable for different settings and requirements.
  • Burning capacity: The WFS 50 incinerator's burning capacity is 50kg/hour. Its design allows continuous operation for at least 12 hours per day. These features also make the WFS 50 suitable for businesses that burn large quantities of waste in a day.
  • The air supply: The WFS 50 model incinerator's forced air system utilizes a mix of primary, secondary, and tertiary air to create and sustain combustion. The introduction of fresh air through the diverse vents allows for sufficient oxygen for the waste to be entirely burned.
  • Materials: The outer casing and internal parts of the WFS 50 are made from highly durable stainless steel and carbon steel. These materials can bear extreme heat and have a long service life, making the products sturdy and dependable.
  • Dust collection: An integrated dust collection system from the WFS manufacturer can filter out harmful particles from smoke before they are emitted. This helps to lessen air pollution and safeguard public health.

To ensure a smooth operation and long-lasting use of the machine, regular maintenance and small repairs of the WFS 50 waste incinerator are essential. Please follow these maintenance tips:

  • Regular inspections: Frequently check the device for any broken, loose, or worn components. Pay special attention to important areas like the burner, exhaust pipe, air ducts, and valves. Replace or repair any faulty parts immediately to prevent further damage from occurring.
  • Clean up: Frequently clear away the ash and trash that build up inside the incinerator during use. If allowed to accumulate for too long, they could block air passages or ignite. Thoroughly cleaning the unit makes it less likely to start fires while improving its burning efficiency.
  • Cleaning the combustion chamber: Use a wire brush to clean the walls of the combustion chamber periodically to remove any ash that has accumulated on the surface and is still there. Because the walls have been cleaned, combustion will improve, and the incinerator's life span will increase.
  • Lubrication: Apply lubricant oil to any movable parts such as pulleys, bearings, and reduction gears once every quarter of an hour. Lubricating tools will reduce the wear and strain on their motors, allowing them to operate flexibly.
  • Familiarity with operating manuals: Users should familiarize themselves with the incinerator's operating manual and maintenance instructions before incinerator operation. The specific model's safety precautions, maintenance guidelines, and key components are all listed in detail in the handbook.

Applications of WFS 50 Incinerators

WFS 50 Incinerators can be used by different sectors. Some of the key applications of these 50 WFS Incinerators are described below:

  • Medical Waste Management:

  • The majority of WFS 50 Incinerators are designed to handle medical waste, which is hazardous and infectious. Hospitals, clinics, and healthcare facilities can use WFS 50 Incinerators to safely get rid of medical waste, such as syringes, bandages, and contaminated materials. Unlike landfills, the WFS 50 Incinerators dispose of this waste properly, ensuring the protection of public health and the environment with every burn.

  • Veterinary Waste Disposal:

  • Just like human healthcare facilities, veterinary practices and livestock farms produce medical waste that must be disposed of safely. WFS 50 Incinerators can be used to incinerate veterinary medical waste, including waste generated from the treatment of animals, thus preventing the spread of animal diseases and protecting biosecurity.

  • Pharmaceutical and Laboratory Waste:

  • Pharmaceutical companies and laboratories generate hazardous waste that must be carefully disposed of to protect public health and the environment. WFS 50 Incinerators offer a safe method for incinerating this laboratory waste, such as expired drugs, chemicals, and contaminated materials, ensuring that it does not pollute the air or land.

  • Industrial Waste Treatment:

  • An incinerator is a good choice for treating industrial waste that cannot be recycled, such as chemical containers, plastic parts, and production residue. WFS 50 Incinerators reduce the volume and environmental impact of this industrial waste through high-temperature combustion.

  • Hazardous and Non-Hazardous Waste Disposal:

  • The WFS 50 Incinerator effectively treats both hazardous and non-hazardous waste streams. It safely disposes of hazardous waste, such as heavy metals and solvents, and reduces the environmental burden of non-hazardous waste, such as municipal solid waste, packaging materials, and plastics, through thermal destruction.

How to choose WFS 50 incinerators

Choosing a WFS 50 incinerator requires careful consideration of several key factors to ensure that the selected machine is in line with needs and environmental responsibilities:

  • Understanding needs and types:

    Users need to start by clarifying their needs. The types of waste that need to be dealt with, coupled with the quantity and frequency of incineration, must be well understood. For example, if industrial hazardous waste is involved, opting for an industrial hazardous waste incinerator is essential. Also, select an appropriate model according to the amount and frequency of waste.

  • Environmental compliance:

    Users need to make sure that the selected incinerator meets local pollution control regulations; otherwise, they could face heavy fines or legal consequences. To this end, users should familiarize themselves with the relevant regulations on waste treatment in their area, as well as the emission standards set by the authorities. When selecting an incinerator, users should prioritize those models that comply with local regulations and make sure that they have the proper licensing and certification for them. If the selected incinerator does not meet regulatory requirements, users could be held responsible for any environmental damage caused by it.

  • Cost and operating expenses:

    Users need to consider all costs associated with the selected incinerator. In addition to the initial purchase cost, operational expenses such as fuel costs, maintenance expenses, and staff training costs should also be taken into account. If the operating cost is too high, it could place a large financial burden on the user's organization.

WFS 50 incinerator FAQ

Q1: What are the benefits of using a WFS 50 hospital incinerator?

A1: The WFS 50 hospital incinerator offers several benefits. It provides safe and efficient disposal of medical waste, reducing the risk of environmental contamination. It has a high-temperature combustion system that ensures complete destruction of hazardous materials. The incinerator is designed to minimize smoke and odor emissions, contributing to a cleaner and healthier community.

Q2: How does the WFS 50 animal incinerator work?

A2: The WFS 50 animal incinerator works by following a systematic process. First, the animal waste is collected and placed in the burn chamber. Then, the incinerator is ignited, and high-temperature combustion is commenced. The remaining ashes can be easily emptied from the burn chamber after the complete combustion of animal waste.

Q3: Is the WFS 50 incinerator safe to use?

A3: Yes, when used according to the manufacturer's instructions, the WFS 50 incinerator is safe. It is equipped with safety features like temperature control and emergency shut-off to prevent accidents.